Now:Mega-tek > products > Level Measurement > Read product
Product Details
MG8900seriesRadar material level Transmitter

● MG8910seriesGuided wave radar level transmitter
● MG8920seriesNon contact type radar level transmitter

  • Product line
  • Principle
  • Technical Data
  • Properties
  • Application

● MG8910seriesGuided wave radar level transmitter
● MG8920seriesNon contact type radar level transmitter

The signal receiver in the probe generates a micro electromagnetic wave along the guided wave antenna, which is generated after the reflection of the surface of the medium. Electromagnetic wave, the circuit module calculates the time difference between the electromagnetic wave and the reflected electromagnetic wave, and can accurately measure the object.Bit height.

Measurement parameters: Liquid level, interface, material level
Type of probe: Single rod type, double rod type, coaxial type, lateral type
Dielectric  constant: ≥1.4
 Electrical  interface: 1/2"NPT/M20×1.5
 input voltage: 13.5~30VDC、With polarity reverse  connection protection
 Process pressure:  0~250bar(0~25MPa)
 Process  temperature: -58~788℉(-50~420℃)
 output signal: Second  tier system 4~20mADC、HART
 measurement  accuracy: ±5mm
 Process display :  4~20mA、Percentage、Engineering  unit
 Length of probe : Rigidity 20~236"(500~6000mm);Flexibility 20~2362"(500~60000mm)
 material :  316LSST、304SST、Ti、304LSST、Ta、Lining PTFE anti-corrosion etc.
 tensile strength  : Flexibility Probe Single rod
 outside diamete0.2"(5mm)3100pound(14kN)
 Flexibility Probe  Double pole
 outside diamete0.2"(5mm)2210pound(10kN)
 Process  connection : Flange connection or threaded connection
 Ex-mark: safe in  nature Ex iaⅡC T1~T6
 explosion-proof  Ex dⅡC T1~T5 Gb
 protection degree:  IP67

● The microwave signal of the guided wave radar can be transmitted  along the antenna, which can eliminate the false echo signal, reduce the loss  of signal and high reliability.;
 ● No drift, not affected by atmospheric conditions and medium density  changes, wetted parts for stainless steel and PTFE material, resistance to acid  and alkali and other corrosive medium;
● Module has good compatibility, and the replacement module does not  need to be calibrated.

Liquid level, interface、Slurry, powder, particles, mixed media, emulsion layer medium, density change of

Navigation
Products
Contact Us
  • Tel: +19196479618
  • E-mail:info@Mega-tekics.com
  • Add: 4030 Wake Forest Road, STE 349, Raleigh, North Carolina, NC 27609